Description:
|
radioManOpRxGain OBJECT-TYPE
SYNTAX INTEGER {manOpActive(1), manOpNotActive(2)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to initiate (manOpActive) or terminate (manOpNotActive) a manual handling of
the gain level.
When the manOpActive value is selected an Abnormal Condition indication is generated. When
the manOpNotActive value is selected the Abnormal Condition indication is removed.
When the manOpActive value is selected, the associated value is contained in the object
ManOpRxGainLevel and, but only in case of Space Diversity configuration, in the object
ManOpRxDivGainLevel."
|
|
|
|
|
|