Description:
|
ntcHWAvailabilityStatus OBJECT-TYPE
SYNTAX INTEGER {inCharge(1), applicationStarting(2), applicationShutdown(3), platformStarting(4), resetting(5), separated(6), unconfigured(7), testing(8), standby(9), dormant(10), unavailable(11)}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Provides more specific information on the state of the unit
in this conceptual row. The status column has eleven
defined values:
inCharge = the unit is fully operational and ready to
perform its desired tasks;
applicationStarting = the application software is starting up;
applicationShutdown = the application software is
shutting down;
platformStarting = Basic platform software is starting up;
resetting = the disk files are closed and hardware reset
is forced;
separated = Only basic OS software is running.
The unit can start application software on request;
unconfigured = The administrative state of the unit is
'missing', disk files are closed and only basic OS
software is running. The unit refuses to start
application software;
testing = Selftests can be performed, only basic OS
are running;
standby = The unit is redundant and is fully operational but not
in charge of operations. It is ready to move to 'inCharge'
state when necessary;
dormant = All connections are physically inactive to
enable removal of the unit without electric disturbance in
the backplane. Only watchdog software is running for a
short duration of time;
unavailable = The unit is not physically present or
cannot be contacted."
|
|