Description:
|
tp5000eModStatusInfo OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A list of operating status parameters for the module.
Example for main shelf status information:
System name: TP5000
IMC time: 2010-03-08 20:33:30
IMC uptime: 7 days 2 hrs 18 mins
IOC1 warmup status: complete (total 1651 secs)
IOC1 state: active
IOC1 uptime: 7 days 2 hrs 18 mins
IOC2 warmup status: n/a
IOC2 state: card not present
IOC2 uptime: card not present
Reference mode: time
Current reference input: GPS
Phase offset: 0 ns
Clock status: normal track
PTP mode eth1: multicast grandmaster
PTP mode eth2: multicast grandmaster
Active alarms: 1
Exp connections: 1,3,6,9
Example for an Ethernet expansion shelf status information:
Expansion shelf: PTP-SyncE
Shelf time: 2010-03-08 20:33:30
Shelf uptime: 7 days 2 hrs 18 mins
Phase Offset: 0 ns
Main Clock status: normal track
Shelf clock status: normal track
Combined Clock status: normal track
PTP mode: multicast grandmaster
SyncE output PQL: 2
Example of an E1/TOD expansion shelf status information:
Expansion shelf: E1-TOD
shelf time : 2010-03-08 20:33:30
shelf uptime : 7 days 2 hrs 18 mins
Phase offset : 0 ns
Main clock status : normal track
Shelf clock status: normal track
Combined Clock status: normal track
E1 output PQL: 2"
|
|
|
|