Description:
|
eventClearedTrap NOTIFICATION-TYPE
OBJECTS {
eventSeqNum,
eventEventId,
eventSetTime,
eventInstanceType,
eventInstanceId,
trapRefSeqNum,
trapSenderNodeId,
sysObjectID}
STATUS current
DESCRIPTION
"This trap is used to inform network management system that a normal
type fault event has been cleared (state set off).
Objects are used as follows:
- eventSeqNum is the sequence number of the this clearing event. Note that
the sequence number of the cleared event is reported in the trapRefSeqNum
object.
- eventEventId specifies what event has been cleared.
- eventSetTime indicates when fault event has been cleared.
- eventInstanceType indicates what kind of object has been
faulty.
- eventInstanceId specifies what instance has been faulty.
- trapRefSeqNum specifies the sequence number of the cleared event (i.e.
the sequence number was assigned for the event in the events table).
- trapSenderNodeId specifies the node ID of the sending network element if
configuring it is supported for the network element, otherwise 0.
- sysObjectID specifies what kind of equipment reports the clearing event.
For more information see the eventTable specification"
|
|
|