Description:
|
fcfLineV28AsynInDteSigMonitored1 OBJECT-TYPE
SYNTAX INTEGER {
none(1),
cts106(33),
dsr107(2),
dcd109(9),
cts106-dsr107(34),
cts106-dcd109(41),
dsr107-dcd109(10),
cts106-dsr107-dcd109(42)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The value of this object defines which circuits
are monitored to eventually generate the
corresponding event when the state of one of them
changes. Secondary circuits may also be
simultaneously monitored (see
fcfLineV28AsynInDteMonitored2).
none : the circuits 106, 107, 109 are not
monitored,
cts106 : the circuit 106 (ready for sending) is
monitored,
dsr107 : the circuit 107 (data set ready) is
monitored,
dcd109 : the circuit 109 (data channel received
line signal detector) is monitored,
cts106-dsr107 : both circuits 106 and 107 are
monitored,
cts106-dcd109 : both circuits 106 and 109 are
monitored,
dsr107-dcd109 : both circuits 107 and 109 are
monitored,
cts106-dsr107-dcd109 : both circuits 106, 107
and 109 are monitored.
The default value is 'cts106'."
|
|
|