Description:
|
fcfLineModDiallingCount OBJECT-TYPE
SYNTAX INTEGER (0..250)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The value of this object is the maximum number of
attempts to complete a sucessfull call for this
serial line interface. A new call request is sent
to the modem when fcfLineModNewDiallingTimer runs
out.
This is a decimal integer in the range 0 to 250.
The default value is '3'."
|
|
|