Description:
|
uxsConfigMemPollMethod OBJECT-TYPE
SYNTAX INTEGER {disabled(1), poll-interval-and-query(2), poll-interval-only(3), query-only(4)}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"&<caiUxOs.137>If set to 'disabled', the agent no more retrieves the memory information (not by polling, nor by get request) and sets all statuses to ok. If set to 'poll-interval-and-query', the agent retrieves the information in both cases (polling and get request). If set to 'poll-interval-only', the agent only retrieves the information by polling, but not by get request. If set to 'query-only', the agent retrieves the information for get requests only."
|
|
|
|
|
|