Description:
|
tnRoeCpriTxGenOffset OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (7))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The time in the unit of 1/100 of nanosecond.
Applicable only when order-info-type is set to seq-num.
Specifies the offset time to start the transmission of
CPRI frames at CPRI egress. CPRI egress starts to send
CPRI frame when the global reference time is greater than
or equal to CPRI Tx gen offset. cpri-tx-gen-offset is
aligned to the time epoc of the time source of this node.
This parameter can be modified only when roe is shutdown."
|
|
|
|