tmnxSasAlarminput4StateChanged NOTIFICATION-TYPE
OBJECTS {tmnxSasAlarmInputNotifyId, tmnxSasAlarmInputDescription, tmnxSasAlarmInputStatus, tmnxSasAlarmOutputSeverity, tmnxSasAlarmInputNotifyMessage, tmnxHwClass}
STATUS current
DESCRIPTION
"[CAUSE] A tmnxSasAlarminput4StateChanged notification is sent when
status of the alarm input on pin four(4) changes.
When this notification is sent, the field
tmnxSasAlarmInputNotifyMessage is populated with either the
tmnxSasAlarmInputTriggerMessage when the alarm is raised, or the
tmnxSasAlarmInputClearMessage when the alarm is cleared.
The trigger or clear actions depend on the polarity of the input as
defined in tmnxSasAlarmInputPolarity.
[EFFECT] A desirable or undesirable event has occurred in the external
equipment connected to the alarm input. Hence the characteristics of
effect and the associated risks vary depending on the nature of the
external equipment being monitored over the alarm input.
[RECOVERY] Check the external equipment, connected to the alarm input
pin four(4), that resulted in this alarm and rectify the problem."
|
|