Main page
OID Repository
https://oid-base.com
Display OID:

{iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) 6527 tmnxBasedProducts(6) aluServiceAggrRouters(1) aluSARMIB(2) aluSARObjs(2) aluHwObjs(2) aluPortObjs(4) aluVoicePortTable(7) aluVoicePortEntry(1) aluVoicePortSignalingType(8)}

aluVoicePortSignalingType(8)

 
 

OID description



 
OID: (ASN.1 notation)
(dot notation)
(OID-IRI notation)

Description:

aluVoicePortSignalingType OBJECT-TYPE
SYNTAX INTEGER {notApplicable(0), privateLineAutomaticRingdown3600(1), -- 3600PLAR
privateLineAutomaticRingdown1511(2), -- 1511PLAR
loopStart3600(3), -- 3600LS
profileOne1511(4), -- 1511Profile1
remoteExtension3600(5), -- 3600RE
fifteenElevenSigSel137(6) -- 1511SN137}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of the object aluVoicePortSignalingType specifies how the
signaling leads operate to establish a call.
This object is valid for fxo and fxs ports only.
privateLineAutomaticRingdown3600 - Does not involve exchange.
When subscriber 1 goes off-hook, cadenced ringing occurs at
subscriber 2. Subscriber 2 answers call by going off-hook.
privateLineAutomaticRingdown1511 - same description as for 3600PLAR but
ABCD bits differ
loopStart3600 - Subscriber applies loop current to seize the line.
Central office signals idle throughout the entire call and does not
provide answer supervision.
profileOne1511 - same as 3600LS but ABCD bits differ
remoteExtension3600 - Subscriber seizes the line by closing loop.
Exchange signals idle throughout the entire call and does not
provide answer supervision. Subscriber can apply a recall signal
by connecting the B lead to earth.
fifteenElevenSigSel137 - aka Exchange_transp
Valid values for fxo ports:
loopStart3600 (muLaw only; default)
profileOne1511 ( aLaw only)
remoteExtension3600 ( aLaw only; default)
fifteenElevenSigSel137 ( aLaw only)
Valid values for fxs ports:
privateLineAutomaticRingdown3600
privateLineAutomaticRingdown1511 ( aLaw only)
loopStart3600 (muLaw only; default)
profileOne1511 ( aLaw only)
remoteExtension3600 ( aLaw only; default)
fifteenElevenSigSel137 ( aLaw only)
To change aluVoicePortSignalingType, the port must be shutdown."