Description:
|
sdpBindCtrlChanPwRequestTimer OBJECT-TYPE
SYNTAX Unsigned32 (0 | 10..65535)
UNITS "seconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of sdpBindCtrlChanPwRequestTimer specifies the request timer
value to be used when control channel for the pseudo-wire path is
enabled for this SDP binding.
An 'inconsistentValue' error is returned if the value of
sdpBindCtrlChanPwRequestTimer is set to non-zero when
sdpBindCtrlChanPwRefreshTimer is set to non-zero.
An 'inconsistentValue' error is returned if the value of
sdpBindCtrlChanPwRequestTimer is set to non-zero when value of either
sdpBindCtrlChanPwRetryTimer or sdpBindCtrlChanPwTimeoutMult is also
set to zero."
DEFVAL {0}
|
|
|
|