Description:
|
tmnxOamVccvTrCtlTestSubMode OBJECT-TYPE
SYNTAX TmnxOamVccvTestSubMode
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxOamVccvTrCtlTestSubMode specifies the type of VCCV
trace route test to perform.
When this object is 'unspecified(1)', the type of VCCV trace route
test to be performed is determined when the test is started, from the
set of tmnxOamVccvTrCtlTable objects configured with non-default
values.
If there is a mismatch between tmnxOamVccvTrCtlTestSubMode and the type
of the pseudowire to be tested, the test will fail. For example, if
tmnxOamVccvTrCtlTestSubMode is 'static(2)', and there is no
TIMETRA-SDP-MIB::sdpBindPwPathTable row for the test's SDP binding,
the test will fail.
The supported object combinations for VCCV trace route tests are
listed in the tmnxOamVccvTrCtlTable DESCRIPTION clause."
DEFVAL {unspecified}
|
|