Description:
|
chasControlActivateTimeout OBJECT-TYPE
SYNTAX Integer32 (0..900)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This value is in seconds. It represents how much time before the
switch automatically falls back to the certified version. This value
is set via the Activate(reload working) cli command.
An Activate reboot must be initiated via the primary CMM and that
the timeout value can be accessed via user interface to the primary CMM
only. After the Activate reboot has been initiated, a timeout will occur
(i.e., an Activate Timeout) at the timeout value specified by the user.
If a reboot cancel has not been received prior to the timeout expiration,
the primary CMM will automatically reboot (i.e., re-reboot) using the
certified configuration. This ensures that an automatic backup reboot is
available using the certified configuration in the event that the user
is unable to interface with primary CMM as a result of the attempted
Activate reboot. If the Activate reboot is successful, the user cancels
the backup reboot via the normal reboot cancellation process (i.e., a
zero value is written for the object chasControlDelayedRebootTimer)."
|
|