Description:
|
optTransportLoop OBJECT-TYPE
SYNTAX INTEGER {
off (0),
terminal (1),
facility (2),
pathFacility (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the loopback status of the Stm1Oc3 Transport for this device.
off (0) - indicates Transport loopback is disabled
terminal (1) - The optical line interface transmit driver is looped back
to the optical receiver. Ultimately the payload is reflected
back to the Switch Fabric and the PCM Highway of the DNX
Backplane.
facility (2) - The Fiber Optic path is looped back to the facility.
pathFacility (3) - The Stm1Oc3 incoming data (Rx) is transmitted back to its source
via the Tx path. The bus that interfaces to the mappers is in
loopback, and the entire payload is returned to its source with a
refreshed frame structure."
|
|
|
|
|
|