Description:
|
optDevCmdStatus OBJECT-TYPE
SYNTAX INTEGER {
-- Initial default status for a row
ready-for-command (0),
-- Device Commands used in SET Command (1..99)
update-config (1),
-- Device Response States used in GET RESPONSE Command (100..199)
update-successful (101),
-- Device Config Error Codes used in GET RESPONSE Command (400..799)
err-general-opt-config-error (400),
err-au4Seq-cannot-be-mixed-framing (402),
err-invalid-opt-dev-command (403),
err-device-is-protection-module (414),
err-invalid-multiplex-map (415),
err-invalid-payload-framing (416),
err-invalid-xlink-nest-num (419),
err-invalid-line-timing (421),
err-ts-alloc-not-applicable (424),
err-xlink-pair-not-applicable (427),
err-data-locked-by-another-user (450),
err-snmp-parse-failed (500),
err-invalid-snmp-type (501),
err-invalid-snmp-var-size (502)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The command status for this link configuration row/record.
The value used in a SET will be replaced by a response
value in the GET RESPONSE indicating success or failure.
Default Response State used in GET RESPONSE Command
ready-for-command (0)
initial default status for a row
Stm1Oc3 Device Cfg Commands used in SET Command (1..99)
update-config(1),
Change existing Stm1Oc3 Device Configuration
Response States used in GET RESPONSE Command (100..199)
update-successful (101)
Device data has been successfully changed
Stm1Oc3 Device Config Error Codes used in GET RESPONSE Command (400..799)
err-general-opt-config-error (400)
Unknown Device configuration error occurred
err-au4Seq-cannot-be-mixed-framing (402)
Au4 sequential mode supports only all-E1 or all-T1 Payloads
err-invalid-opt-dev-command (403)
Unrecognized device command-action
err-device-is-protection-module (414)
Can't configure Device designated as Protection (odd # slot)
err-invalid-multiplex-map (415)
Configured multiplexing structure not valid for device type
err-invalid-payload-framing (416)
Unrecognized payload group type
err-invalid-xlink-nest-num (419)
X-Link cannot be assigned to selected Nest
err-invalid-line-timing (421)
Unrecognized clock setting
err-ts-alloc-not-applicable (424)
Timeslot Alloc can only be configured for STM1 or OC3
cards in Standalone DNX systems
err-xlink-pair-not-applicable (427)
X-Link assignement can only be changed for STM1X or
OC3X cards in DNX88 systems.
err-data-locked-by-another-user (450)
Another administrative user is making changes to this
part of the system via a terminal session. Check Event
Log for user name.
err-snmp-parse-failed (500)
Agent could not parse variable
err-invalid-snmp-type (501)
Variable ASN type does not match Agent defined type
err-invalid-snmp-var-size (502)
Variable size is too big"
|
|
|
|
|
|