Description:
|
ds0dpDiagDropLoop OBJECT-TYPE
SYNTAX INTEGER {
off (0),
ocu (40),
csu (41),
ds0ToDrop (42),
local(43),
ds0FromDrop (49)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Determines the current latching DS0 Dataport loopback code
on the STP drop side (4 wire anolog side) for this port.
In order to turn on a loop, the port must be configured In Service
with a Connection.
off (0) - indicates drop side loopback is disabled
ocu (40) - triggers the DS0DP to send a standard DDS OCU
loop code towards the drop side.
csu (41) - triggers the DS0DP to send a standard DDS CSU
loop code towards the drop side.
ds0ToDrop (42) - loops the DS0 data towards the drop side.
local (43) - the STP/PATCH PANEL output data enters the DS0DP
and is looped back toward the four-wire drop. Also,
the DS0-DP sends the DDS Mux-Out-Of-Sync-Code in place
of the four-wire loop data towards the network.
ds0FromDrop (49) - loops the DS0 data from the drop side."
|
|
|
|
|
|