Description:
|
oT1E1CfgLBO OBJECT-TYPE
SYNTAX INTEGER {
e1-shortHaul-0-6db (1),
e1-longHaul-0-34db (2),
t1-longHaul-0-0db (3),
t1-longHaul-7-5db (4),
t1-longHaul-15-0db (5),
t1-longHaul-22-5db (6),
t1-shortHaul-0-133ft (7),
t1-shortHaul-133-266ft (8),
t1-shortHaul-266-399ft (9),
t1-shortHaul-399-533ft (10),
t1-shortHaul-533-655ft (11)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Determines the type of Line Build Out (LBO) used on the link.
Choose between short haul or long haul designations but this varies
between T1 & E1. E1 LBO is defined by authentication of signal
presented to receiving circuitry while T1 LBO can be defined by
cable length or signal.
e1-shortHaul-0-6db (1) 0 to -6 decibel loss
e1-longHaul-0-34db (2) 0 to -34 decibel loss
t1-longHaul-0-0db (3) 0.0 decibel loss
t1-longHaul-7-5db (4) 0.0 to -7.5 decibel loss
t1-longHaul-15-0db (5) 0.0 to -15.0 decibel loss
t1-longHaul-22-5db (6) 0.0 to -22.5 decibel loss
t1-shortHaul-0-133ft (7) 0 to 133 feet of cable
t1-shortHaul-133-266ft (8) 133 to 266 feet of cable
t1-shortHaul-266-399ft (9) 266 to 399 feet of cable
t1-shortHaul-399-533ft (10) 399 to 533 feet of cable
t1-shortHaul-533-655ft (11) 533 to 655 feet of cable"
|
|
|
|
|
|