Main page
OID Repository
https://oid-base.com
Display OID:

{iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) 644 eriProducts(2) dnx(4) sysMgr(1) eXpansionNestAdmin(11) xSlotTable(2) xSlotEntry(1) xSlotCmdStatus(10)}

xSlotCmdStatus(10)

 
 

OID description



 
OID: (ASN.1 notation)
(dot notation)
(OID-IRI notation)

Description:

xSlotCmdStatus OBJECT-TYPE
SYNTAX INTEGER {
-- Initial default status for a row
ready-for-command (0),
-- Slot Device Commands used in SET Command (1..99)
update-slot-config (1),
delete-slot-config (2),
ndr-switchover (10),
ndr-restore (11),

-- Response States used in GET RESPONSE Command (100..199)
update-successful (101),
delete-successful (102),
switch-successful (110),
restore-successful (111),

-- Slot Config Error Codes used in GET RESPONSE Command (200..799)
err-general-slot-config-error (200),
err-invalid-slot-type (201),
err-invalid-slot-command (202),
err-invalid-slot-name (203),
err-redundancy-disabled (204),
err-cannot-chg-sys-device (205),
err-invalid-redundancy-state (207),
err-cannot-delete-online-device (208),
err-data-locked-by-another-user (450),
err-snmp-parse-failed (500),
err-invalid-snmp-type (501),
err-invalid-snmp-var-size (502)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The command status for this slot configuration row/record.
The value used in a SET will be replaced by a response
value in the GET RESPONSE indicating success or failure.

Default Response State used in GET RESPONSE Command
ready-for-command (0)
initial default status for a row

Slot Device Commands used in SET Command (1..99)
update-slot-config (1)
change an aspect of current slot configuration
delete-slot-config (2)
remove existing Slot Configuration. Deleting the Slot
Configuration using the Slot Command Status will result
in the removal of all configured connections associated
with that slot number.
ndr-switchover (10)
force a switchover to the Standby device
ndr-restore (11)
force a restore back to the original device

Response States used in GET RESPONSE Command (100..199)
update-successful (101)
slot data has been successfully changed
delete-successful (102)
slot data has been successfully removed
switch-successful (110)
Slot N+1 Redundancy device has been successfully
switched over to Standby device
restore-successful (111)
Slot N+1 Redundancy device has been successfully
restored back to Primary device

Slot Config Error Codes used in GET RESPONSE Command (200..799)
err-general-slot-config-error (200)
Unknown slot configuration error occurred.
err-invalid-slot-type (201)
Configured slot type not in valid range
err-invalid-slot-command (202)
Unrecognized slot command-action
err-invalid-slot-name (203)
Configured slot name too long
err-redundancy-disabled (204)
Redundancy disabled on this system or does not apply to
device type
err-cannot-chg-sys-device (205)
System Device type does not support configuration change
err-invalid-redundancy-state (207)
Redundancy state does not apply or invalid
err-cannot-delete-online-device (208)
Device cannot be present when deleting configuration
err-data-locked-by-another-user (450)
Another administrative user is making changes to this
part of the system via a terminal session. Check Event
Log for user name
err-snmp-parse-failed (500)
Agent could not parse variable
err-invalid-snmp-type (501)
Variable ASN type does not match Agent defined type
err-invalid-snmp-var-size (502)
Variable size is too big"



Classification:

MIB object for network management

 
See classes of OIDs

Note to implementers:




 
 
Short link:


Parent OID: xSlotEntry(1) First sibling OID: xSlotDeviceType(2) Previous sibling OID: xSlotMiscState(9) Next sibling OID: xSlotRawDeviceState(11) Last sibling OID: xSlotRawDeviceState(11)