Description:
|
mscFrUniSigCallSetupTimer OBJECT-TYPE
SYNTAX Unsigned32 (1..255)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This attribute specifies the time the network waits for a response to
the SETUP message sent to the called user. Upon timer expiry, the
SETUP message is retransmitted. The second expiry of this timer
causes the call to be cleared."
DEFVAL { 4 }
|
|
|