Description:
|
atmIfVpcVpdTmAbrMaxTimeBetweenRmCells OBJECT-TYPE
SYNTAX Unsigned32 (781 | 1563 | 3125 | 6250 | 12500 | 25000 | 50000 | 100000 | 16777216)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This attribute specifies the TRM parameter for this connection.
TRM provides an lower bound on the time interval between forward
Resource Management (RM) cells for an ABR source. Since the last
forward RM cell was sent, if at least TRM time has elapsed since
and at least two other cells have been sent, then the next cell to be
transmitted would be a forward RM cell.
This attribute is ignored under all conditions where the operational
attribute abrConnectionType has the value erSwitch.
The provisioned value of 781 is signalled as TRM = 0, in the ABR
Additional Parameters Information Element.
1563 is signalled as TRM = 1.
3125 is signalled as TRM = 2.
6250 is signalled as TRM = 3.
12500 is signalled as TRM = 4
25000 is signalled as TRM = 5.
50000 is signalled as TRM = 6.
100000 is signalled as TRM = 7.
VALUES (
16777216 = sameAsCa
)"
DEFVAL { 16777216 }
|
|
|