rfAmpRFPortMasterAttenuationControl OBJECT-TYPE
SYNTAX INTEGER {low(1), high(2), pad(3)}
ACCESS read-write
STATUS optional
DESCRIPTION
"Reports and Controls the state of a reverse path attenuation switch
that affects ALL ports.
low - No attenuation on the reverse path.
high - Typically high amount of attenuation on the reverse path.
This value may not be available for all switches.
pad - Typically a small amount of attenuation on the reverse
path. This value may not be available for all switches.
Note that the values for the object
rfAmpRFPortReverseAttenuationControl do NOT change when this object
is accessed."
|
|