Description:
|
v52LinkCheckId OBJECT-TYPE
SYNTAX INTEGER{activated(1),
notActivated(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Valid values for this variable are activated and
notActivated and the default is notActivated.
Set this variable to 'activated' to request check
v52LinkId with the LE side link id. When the checkId
is finished, this value will be 'notActivated'.
Setting the value to 'notActivated' has no impact.
A link identification check can successfully be started
only when the link is operational. This link identification
procedure can be initiated from either the AN or LE side
but LE has priority over AN initiated request in case of
collision of requests from AN and LE, in which case, the
v52LinkCheckId request will fail.
It is up to the system management to initiate the link
identification or not. It can be performed by the system
management on a timed basis, or be applied after
re-provisioning."
REFERENCE
"Section 16.2.4.3.5 - ETSI EN 300 347-1 V2.2.2 (1999-12)"
DEFVAL { notActivated }
|
|