Description:
|
sechtor100ConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF Sechtor100ConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains redundancy variables and environmental
variables for monitoring fans and thermometers.
For redundancy, the peer MAC address is maintained in this
table. Also, one variable specifies whether redundancy is
enabled or not.
There are two thermometers on the Sechtor 100 board. In this
MIB, thermometers 'A' and 'B' are used to differentiate
these two thermometers:
Thermometer A - the thermometer located near the 750
processor. It is expected that this thermometer have a higher
temperature reading than thermometer B because of the heat
generated by the processor. It is recommended that a higher
upper threshold is set for this thermometer.
Thermometer B - the thermometer located near the outlet on
the right side of the Sechtor 100 board.
The profile for this table will be auto-created as 1/1 with
the sechtor100RedundancyEnable variable set to FALSE.
This profile should not be deleted except for the following
two cases:
1) When a unit operating in simplex mode is intended to be used
in duplex mode as the slot 2 of the redundant system. The
user needs to create a 1/2 profile.
2) The unit configured as slot 2 of a redundant system is intended
to be used in simplex mode. Then the 1/2 profile should be
deleted and replaced with a 1/1 profile."
|
|
|