h323DebugSuppTraceEngineProvision OBJECT-TYPE
SYNTAX MxEnableState
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enables/disables traces related to interaction between
the H.323 classes, MX-H323-REGISTRATION-MIB,
MX-H323-ATTRIBUTES-MIB and MX-H323-ALIASES-MIB. These
traces are used to track exactly where and when a
problem occurred.
The traces are sent as Syslog messages you can see with
a Syslog daemon. The Syslog functionality of the
endpoint has to be configured with the debug level
(syslogMsgMaxSeverity of MX-SYSLOG-MIB) set to 'debug'."
DEFVAL {disable}
|
|
|