Description:
|
fxsMeterPauseDuration OBJECT-TYPE
SYNTAX Unsigned32 (100..600)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is the pause duration (voltage is OFF) in ms.
The clock precision is 10 ms, i.e. you can
request 327 ms, but the system will pause for
327 +/- 10 ms."
DEFVAL {360}
|
|
|