Description:
|
h323SingleRegCallSignalingPortSource OBJECT-TYPE
SYNTAX INTEGER {dynamic(0), static(1)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the source of the local call signaling port. Applies only if the unit
is configured to register. If the unit is not configured to register, it uses
the well-known call signaling port (1720) for its local call signaling port.
The local call signaling port is used to exchange Q.931 messages with
gatekeepers and other H.323 endpoints. Examples of Q.931 messages are SETUP,
CONNECT and RELEASE COMPLETE.
dynamic : the unit chooses its local call signaling port at run time.
static : the administrator sets the local call signaling port."
DEFVAL {dynamic}
|
|
|