Description:
|
clockReferenceSource OBJECT-TYPE
SYNTAX OCTET STRING ( SIZE(0..255) )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Clock Reference Source
Indicates the preferred synchronisation source(s) to use for
the internal clock. Refer to the ClockReferenceList parameter
for a list of available clock references for the platform.
When the value is empty, the platform will automatically
choose the synchronisation source.
When a source or a list of sources are specified, the internal
clock is synchronised with the first source that offers a
valid signal. The only exception is the SYNCIN port (not
present on all platforms), which is always used when
encountered in the list.
Depending on the platform, two string separators may be used:
* ',' (comma): List synchronisation sources, per priority
(Sentinel and G7 platforms only).
* ';' (semicolon): Adding a second synchronisation source
(3xxx platform only)
Examples:
* For 44xx: 'Bri1'
* For C7xx: 'BRI1, BRI2'
* For 3xxx: 'Slot2/E1T1'
* For 3xxx: 'Slot2/Bri0; Slot3/Bri2'
* For Sentinel 400: 'Slot1/E1T1, Slot2/BRI1, Slot2/BRI2,
SYNCIN'
* For Sentinel 100 and G7: 'BRI1, BRI2, PRI1, PRI2, SYNCIN'
* Any platform: ''"
DEFVAL {""}
|
|
|
|