Description:
|
fxoLinkStateLinkState OBJECT-TYPE
SYNTAX INTEGER {unknown(100), up(200), down(300)}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"FXO Line State
Link state as reported by the link state verification
mechanism. The link state verification can be enabled by
using the FxoLinkStateVerification parameter object.
The unit does not automatically detect when a previously
connected port has changed to the disconnected status. The
unit only detects the change of status when it attempts to
use the port or after a restart.
The unit automatically detects within seconds when a
disconnected port becomes connected.
* Unknown: The line fault detection is disabled.
* Up: When last polled, the line was connected.
* Down: When last polled, the line was disconnected."
|
|