Description:
|
chipModFlag OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Class 1 General
0x80 Reset Concentrator
(1=Execute 0=No Action)
0x40 Power supply switch
(1=Backup 0=Primary)
0x20 Reserved for internal use
0x10 Reserved for internal use
0x08 Test LED
(1=Execute 0=No Action)
Class 2 General
0x80 Reset Module
(1=Execute 0=No Action)
0x40 Reset mastership
(1=Execute 0=No Action)
Class 3 General
0x80 Reset Module
(1=Execute 0=No Action)
0x40 Configure to DIP
(1=Execute 0=No Action)
Class 3 Specific to 5104M-FIB
0x20 Reset Ports
(1=Execute 0=No Action)
0x10 Lowlight Warning
(1=Enable 0=Disable)*
Class 3 Specific to 5108M-UTP
0x20 Fifo Fill Level
(1=7 Bits 0=8 Bits) *
0x10 Crossover Mode
(1=Enable 0=Disable) *
Class 3 Specific to 5108M-TP
0x10 Crossover Mode
(1=Enable 0=Disable)*
* Indicates which flags are meaningful
in the module specific DipFlag variable.
Class 4 General
0x80 Reset module
0x40 Configure to DIP
0x10 Save current configuration
0x08 Revert configuration
0x04 Reserved for internal use
Class 5 General
0x80 Reset module
(1=Execute 0=No Action)
0x40 Configure to DIP
(1=Execute 0=No Action)
Class 6 General
0x80 Reset module
0x40 Configure to DIP
0x20 Set module bypass state"
|
|
|
|
|
|