thermalPowerOnDelay OBJECT-TYPE
SYNTAX Unsigned32 (2..50)
UNITS "250 Milliseconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This delay specifies the time between the Thermal Shutdown Controller detecting
that the Power On Threshold has been reached and when it actually switches
the unit back on. Its purpose is to allow power on the remainder of the board
to stabilize. Serial communications are blocked during this delay, so it should
be chosen carefully. The delay is specified in multiples of 50 milliseconds
2 to 50 ( 100ms - 2500ms ). The default is value is 5 yielding a delay
of 250ms."