Description:
|
clientServiceTypeLogin OBJECT-TYPE
SYNTAX INTEGER {disable(0), enable(1)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When this OID is set to enabled(1) the controller sets the Service-Type
attribute of a station's Access-Request to 'Login'. When this OID is set to
disabled(0) the controller sets the Service-Type attribute of a station's
Access-Request to 'Framed'. By default this OID is set to 'disabled'.
You cannot use RADIUS servers to authenticate administrators
for local server access when this OID is set to 'enabled'."
|
|
|
|