Description:
|
padApplAdminPADDialCallTimeout OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The dial port call timeout specifies the value of a timer that is used on dial PAD ports to free them when no data call is established.
Values are: 0 - disabled, 1 - 255 ten second increments. The default value is 9.
The timer is started when the user makes a telephone connection to a dial port and when a data call on a dial port is cleared. If the timer expires before a data call is established, the PAD drops the physical telephone connection."
|
|
|
|
|
|