Description:
|
nvmIsdnSignalingCallingAddress OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..131))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"NAME = ;
DESC = The ISDN Address to be assigned to this signaling \
channel. More specifically, this is the 'Calling Address \
information element' as being passed to the switch \
in outgoing call setup messages. \
It can be an EAZ (1TR6), a calling number (DSS1, \
ETSI)or any other number necessary to identify a \
signaling interface. If there is no such number defined \
or required, this is a zero length string. It is represented \
in DisplayString form. \
Incoming calls can also be identified by this number. \
If the Directory Number, i.e. the Called Number in \
incoming calls, is different to this number, the \
isdnDirectoryTable has to be used to specify all \
possible Directory Numbers. \
The format of this information largely depends on the \
type of switch or PBX the device is connected to. Therefore, \
the detailed format of this information is not \
specified and is implementation dependent. \
If possible, the agent should implement this information \
using the E.164 number format. In this case, the number \
must start with '+'. Otherwise, IA5 number digits must \
be used. (Configuration) ;
HELP = ;
CAPABILITIES = ;"
REFERENCE
"ITU-T E.164, Q.931 chapter 4.5.10"
DEFVAL { "" }
|
|