Description:
|
dl56SnmpTrapRetryTime OBJECT-TYPE
SYNTAX INTEGER (0..60)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Specifies the number of minutes the unit will wait
before retrying a TRAP PDU.
This feature is inconsistent with the definition of SNMP;
when dl56SnmpTrapRetryTime is 0 (the factory default),
TRAP PDUs will be sent only once, in conformance with SNMP.
To acknowledge a TRAP PDU, the SNMP Manager must
set dl56AlarmCount (see dl56AlarmTable, below) to 0.
The dl56StartAlarm and dl56EndAlarm TRAP-TYPEs contain
the information required to index into dl56AlarmTable.
As of this writing (V 1.2, 6/29/95)
dl56SnmpTrapRetryTime is not implemented, and does not work.
This feature will be activated in future revs of the product."
|
|