Description:
|
atmGenRateQueue OBJECT-TYPE
SYNTAX INTEGER (0..135150)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The value of this object can be set to any value in
the range 0 to 30720 for E3, the range 0 to 36864 for DS3, and
the range 0 to 135150 for OC3. The combination of all the values
of all the rate queue objects must equal 30720 for E3,
36864 for DS3, and 135150 for OC3. Thus,
if this object has a value of 36864 for DS3, then the values
of the rest of the objects cannot be set to anything
other than 0.
The value of any rate queue object is rounded down to
the nearest multiple of 10."
DEFVAL { 0 }
|
|