Description:
|
ppmMIBCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statements for SNMP Agents that implement this
Printer Port Monitor MIB."
MODULE -- this module
MANDATORY-GROUPS { ppmGeneralGroup, ppmPrinterGroup, ppmPortGroup }
OBJECT ppmPrinterIEEE1284DeviceId
SYNTAX OCTET STRING (SIZE(0..255))
DESCRIPTION
"At least 255 octets maximum string length MUST be supported
by all implementations of this object. The 'MANUFACTURER' (or
'MFG') and 'MODEL' (or 'MDL') fields MUST be contained within
the first 255 octets of this object (to prevent truncation of
critical information across gateways and mid-level managers).
Implementations that support less than the 1023 octets maximum
string length MUST only truncate complete fields (i.e., keyword,
colon, value(s), and semicolon)."
|
|
|
|