condPriority OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Specifies the conductor priority for a CobraNet device. The
device with the highest priority will become the conductor for
the network.
0 - Never Conduct
1 - Lowest conductor priority
255 - Highest conductor priority"