Description:
|
modeRateControl OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Selects latency and sample rate operating mode for the interface.
note that this variable is read-only. operating mode can only be
changed by local host through HMI.
The following modes are supported:
0x701 - 5-1/3ms latency, 96Khz sample rate
0x700 - 10-2/3ms latency, 48Khz sample rate
0x600 - 5-1/3ms latency, 48Khz sample rate
0x601 - 2-2/3ms latency, 96Khz sample rate
0x500 - 2-2/3ms latency, 48Khz sample rate
0x501 - 1-1/3ms latency, 96Khz sample rate
0x400 - 1-1/3ms latency, 48Khz sample rate
0x401 - 2/3ms latency, 96Khz sample rate
0x300 - 2/3ms latency, 48Khz sample rate
0x301 - 1/3ms latency, 96Khz sample rate
0x200 - 1/3ms latency, 48Khz sample rate
0x201 - 1/6ms latency, 96Khz sample rate"
|
|