Main page
OID Repository
https://oid-base.com
Display OID:

{iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) 2606 cmcTc(4) cmcTcStatus(2) cmcTcStatusSensorUnit2(4) cmcTcStatusUnit2Outputs(6) cmcTcUnit2OutputTable(2) cmcTcUnit2OutputEntry(1) unit2OutputType(2)}

unit2OutputType(2)

 
 

OID description



 
OID: (ASN.1 notation)
(dot notation)
(OID-IRI notation)

Description:

unit2OutputType OBJECT-TYPE
SYNTAX INTEGER {
notAvail (1),
failure (2),
overflow (3),
doorLock (4),
univLock1 (5),
univLock2 (6),
fan (7),
fanSpeedContr (8),
universalOut (9),
roomLock(10),
powerOut(11),
doorLockMaster(12),
doorLockFRi (13),
setpoint (14),
setpointTimax (15),
hysteresisRCT (16),
commandRCT (17),
relayPSM (18),
setHighPSM (19),
setLowPSM (20),
setpointRTT (21),
setTimaxRTT (22),
powerOut1(23),
doorMagnet(24),
controlModeLCP (30),
minFanSpeedLCP (31),
minDeltaTLCP (32),
maxDeltaTLCP (33),
kPLCP (34),
kILCP (35),
kDLCP (36),
flowRateLCP(37),
cwValueLCP (38),
deltaTLCP (39),
ctrModLCP (40),
voltHighPSM (42),
voltLowPSM (43),
ampHighPSM (44),
ampLowPSM (45),
commandPSM (46)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Type of output which is connected to sensor unit 2 to output[unit2OutputIndex]
1: no output connected
2: output failure
3: value overflow
4: output type 1, door locking TS8,Ergoform
5: output type 2, universal lock 1, lock with power
6: output type 3, universal lock 2, unlock with power
7: output type 4, fan relay
8: output type 5, fan controlled
9: output type 6, universal relay output
10: output type 7, room door lock
11: output type 8, power output
12: output type 9, door lock with Master key
13: output type 10, door lock FR(i)
14: setpoint (FCS, RTT)
15: setpoint temperature monitoring (RTT)
16: hysteresis of setpoint (RCT)
17: command for remote control of RCT
18: relay PSM, 1=On, 0=Off
19: high setpoint current monitoring PSM
20: low setpoint current monitoring PSM
21: setpoint temperature RTT
22: setpoint temperature monitoring RTT
23: power output 20A
24: door magnet (automatic door release)
30: control mode LCP
31: min fan speed (fan control) LCP
32: min delta T (fan control) LCP
33: max delta T (fan control) LCP
34: PID controller, KP, LCP
35: PID controller, KI, LCP
36 PID controller, KD, LCP
37 flowrate flowmeter, LCP
38: cw value of water (default: 4187) LCP
39: deltaT, LCP
40: control mode, LCP
42: setpoint high voltage PSM
43: setpoint low voltage PSM
44: setpoint high current PSM
45: setpoint low current PSM
46: command PSM"



Classification:

MIB object for network management

 
See classes of OIDs

Note to implementers:




 
 
Short link:


Parent OID: cmcTcUnit2OutputEntry(1) First sibling OID: unit2OutputIndex(1) Previous sibling OID: unit2OutputIndex(1) Next sibling OID: unit2OutputText(3) Last sibling OID: unit2OutputTimeoutAction(9)