Description:
|
pmMIRstFlushIndicationThreshold OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This indicates the number of flush indications to go before
timer method triggers. (i.e) The number of flush indications
to trigger the FlushInterval Timer.
This value can be configurable only when pmMIRstFlushInterval
is other than default value.
When the value is retained as default value and flush interval
is being configured other than default value(0), then
global flushing will happen.
When this value is non-default and the flush interval is being
configured other than default value(0), then the port
based flushing will happen until the actual flush indication
reaches the threshold. Once the threshold is reached, timer
will be started and during timer expiry gloabl flushing will
happen."
DEFVAL {0}
|
|