Description:
|
cableDiagResultStatusPairA OBJECT-TYPE
SYNTAX INTEGER {notTestedYet(1), ok(2), open(3), short(4), impedanceMismatch(8), failed(9), notSupported(10), noCable(11)}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The result of cable diagnostics. If there is no fault
on the cable, the value is ok(2). Value notTestedYet(1)
means the pair is not tested yet. Value ok(2) means the
pair works well. Value open(3) means there is a lack of
continuity between pins at each end of the pair. Value
short(4) means conductors are short-circuited together on
the pair. Value openShort(5) means the pair has open
and short issues. Value crosstalk(6) means the pair is
incorrectly connected at one end. Value unknown(7) means
pair has an error matching none of the above. Value
impedanceMismatch(8) means different quality cables
connected together. Value failed(9) means test failed.
Value notSupported(10) means cable diagnostics is not
supported. Value noCable(11) means there is no connected
cable."
|
|
|
|
|
|