Description:
|
aviciBayVoltageNotification NOTIFICATION-TYPE
OBJECTS {
aviciBayIndex,
aviciBayVoltageIndex,
aviciBayVoltage,
aviciBayVoltageStatus,
aviciSysTrapDescr
}
STATUS current
DESCRIPTION
"A Voltage notification is sent when a change is detected in the 5
volt backplane communication rails. These backplane
communication rails are used by the bay controller to
communicate with the occupant of a given slot. There are 8
rails, each servicing the slots in one half of a shelf in the
bay (aviciBayVoltageIndex == rail):
Rail Slots
==============
1 1 - 5
2 6 - 10
3 11 - 15
4 16 - 20
5 21 - 25
6 26 - 30
7 31 - 35
8 36 - 40
If the voltage is out of specification, the communication path
will not function. When a given backplane communication channel
is not functioning, modules serviced by this rail cannot be
discovered (if a module is inserted) and will not be authorized
to boot (if an existing module reboots). The current voltage is
reported in the aviciBayVoltage object. A human readable
description of the event triggering this notification is
included in the aviciSysTrapDescr object."
|
|
|
|