{iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) 232 cpqHealth(6) cpqHeComponent(2) cpqHeThermal(6) cpqHeTemperatureTable(8) cpqHeTemperatureEntry(1) cpqHeTemperatureThresholdType(7)}

cpqHeTemperatureThresholdType(7)

 
 

OID description



   
OID: (ASN.1 notation)
(dot notation)
(OID-IRI notation)

Description:

cpqHeTemperatureThresholdType OBJECT-TYPE
SYNTAX INTEGER {other(1), blowout(5), caution(9), critical(15), noreaction(16)}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This specifies the type of this instance of temperature
sensor.
This value will be one of the following:
other(1)
Temperature threshold type could not be determined.
blowout(5)
If a blowout(5) temperature sensor reaches its threshold,
the fan or fans in the area of the temperature sensor will
increase in speed in an attempt to reduce the temperature
before a caution or critical threshold is reached.
caution(9)
If a caution(9) temperature sensor reaches its threshold,
the cpqHeTemperatureCondition will be set to degraded(3)
and the system will either continue or shutdown depending
on the setting of cpqHeThermalDegradedAction.
critical(15)
If a critical(15) temperature sensor reaches its threshold,
the cpqHeTemperatureCondition will be set to failed(4)
and the system will shutdown.
noreaction(16)
this value will be defined when a threshold value is zero and
system will not react on those sensor as those threshold
sensors are meant for display purpose only."


 
 