Main page
OID Repository
https://oid-base.com
Display OID:

{iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) 232 cpqHealth(6) cpqHeComponent(2) cpqHeThermal(6) cpqHeTemperatureTable(8) cpqHeTemperatureEntry(1) cpqHeTemperatureThreshold(5)}

cpqHeTemperatureThreshold(5)

 
 

OID description



   
OID: (ASN.1 notation)
(dot notation)
(OID-IRI notation)

Description:

cpqHeTemperatureThreshold OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This is the shutdown threshold temperature sensor setting
in degrees celsius. This is the temperature in which the
sensor will be considered to be in a failed state thus
causing the system to be shutdown.
If this value cannot be determined by software, then a value
of -99 will be returned.
Only the Ambient zone type allows setting of the threshold
temperature."


 
 
Short link:


Parent OID: cpqHeTemperatureEntry(1) First sibling OID: cpqHeTemperatureChassis(1) Previous sibling OID: cpqHeTemperatureCelsius(4) Next sibling OID: cpqHeTemperatureCondition(6) Last sibling OID: cpqHeTemperatureHwLocation(8)