Description:
|
xldv20pmThresholdLimitTable OBJECT-TYPE
-- info-IMPL: V2.0->
-- info-VERCTRL: -
SYNTAX SEQUENCE OF Xldv20pmThresholdLimitEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The threshold limit table for all interface.
This table associates threshold limit index/PM counter
pairs with threshold limit values for a 15 minutes
interval. Entries with same threshold limit index
belong to the same threshold limit profile.
Each of the following TC-adaptor types are available
and can be configured: adc, s1n, s3n, d3n, e3n.
A crossing of a threshold limit leads to a
threshold crossing alert."
-- DEFAULT test-function-async fsnPmThlEntryTest
-- DEFAULT next-function-async fsnPmThlEntryNext
-- DEFAULT set-function-async fsnPmThlEntrySet
-- DEFAULT get-function-async fsnPmThlEntryGet
|
|
|
|