gnSSMStatStatus OBJECT-TYPE
SYNTAX OCTET STRING(SIZE(2))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Alarm status of SSM. Bit 1 is MSB, bit=1 when alarm active.
bit 1 = Unlock
bit 2 = Out Of Range
bit 3 = Primary Clock Source Failure
bit 4 = Secondary Clock Source Failure"