Description:
|
uemSensorTable OBJECT-TYPE
SYNTAX SEQUENCE OF UemSensorTableEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"All fan, temperature and voltage sensors are collected in this table.
All these devices are similar in that they monitor 5 value ranges:
low critical, low warning, normal, high warning, high critical.
Notifications (trap messages) are sent whenever the monitored value moves
from one value range to another. The guard points defining the 5 monitored
regions (or range of values) are read-write allowing remote configuration
by an SNMP management console.
There may be zero or more rows in this table. Each row in the table contains
information about a single sensor. One column, uemSensorType, identifies
the type of sensor as fan, temp or voltage. Another column, uemSensorStatus,
identifies where in the 5 possible ranges the monitored device is currently
operating within. Each row is linked to a parent EnvMonitor row to further
identify its location within the server."
|
|
|
|
|
|