Description:
|
fibTmuPortsTauAllowedAddrLoaded OBJECT-TYPE
SYNTAX INTEGER {
addr-not-loaded(1),
loaded-not-active(2),
loaded-and-active(3)}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This is the status of fibTmuPortsTauAllowedAddr.
When reading, the possible values are as follows:
addr-not-loaded indicates the value in
fibTmuPortsTauAllowedAddr is meaningless. No
security address has been loaded for this port.
loaded-not-active indicates the value in
fibTmuPortsTauAllowedAddr is stored in non
volatile memory but security action for this
port is not active. This happens when address
is loaded while security action for the
Tmu system is disabled (fibTmuSecurityModeRun
has bit0 reset).
loaded-and-active indicates the value in
fibTmuPortsTauAllowedAddr is loaded in non
volatile memory and security is active on
this port. This means that if a station is
directly connected to this port then it must
have the specified physical address or this
port will automatically close.
As for writing, this object can be written
only if its value is either 'loaded-not-active'
or 'loaded-and-active' and the only value
allowed is addr-not-loaded. In that case,
'fibTmuPortsTauAllowedAddr' is erased from the
non-volatile memory and 'fibTmuNumStationLeft'
is incremented. If port has been closed
because of security (fibTmuPortsPortState had
bit9 set) then it will open (provided it has not
been closed because of some other reason).
This command only affects ports on Tau. If there is
no Tau attached when command is issued, then it is
stored in memory and goes into effect when a Tau
is attached. This command will have no effect of
a station directly attached to the Tmu. To affect
such ports, use 'fibTmuPortsAllowedAddrLoaded'"
|
|
|
|