Description:
|
fibTmuPortsPortState OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bit map describing the indicated port:
Bit1 (0x02) -
No such port. Index is out of bounds.
Either a Tau is connected and the specified
port number is larger than the number
of ports on the Tau currently connected
or a single station is directly attached and
the specified port number is larger than
1.
Bit2 (0x04) -
It has not yet been determined what is
connected to the specified Tmu port. It
may later be found to be either a single
station of a Tau.
Bit3 (0x08) -
Port is attached. This means that the token
ring goes through the station related to
this port.
Bit4 (0x10) -
Phantom signal is 'on' for this port.
Bit5 (0x20) -
Port is detached because of a request
from manager.
Bit6 (0x40) -
Port is temporarily detached because
of a temporary error or because it is
in a transition state.
Bit7 (0x80) -
Port is detached because of an error and
will remain so until phantom goes down and
up again.
Bit8 (0x100) -
Port is a Tmu port attached to a single
station.
Bit9 (0x200) -
Port is detached because of security
violation and will remain so until phantom
goes down and up again or until manager
releases the lock."
|
|
|
|