Description:
|
prptrSecurityGroupAutoLearnMode OBJECT-TYPE
SYNTAX INTEGER {
other(1),
enable(2),
disable(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION "When this variable is set to enable(2)
the repeater will enable auto learn mode for all
10BASET ports in LC342S card, and for ports 1-8
in LC348S card.
When this variable is set to disable(3)
the repeater will disable auto learn mode for all
10BASET ports in LC342S card, and for ports 1-8
in LC348S card.
The value other(1) is returned whenever
the auto learn mode is unknown. This value may not
be written into the agent."
|
|
|
|